This roof assembly appears to be quite cathedral but if i realize effectively its not vented at all, but has generous over sheathing foam. Is that this thought of a vapour safe assembly contemplating this article suggests "Put in rigid foam insulation higher than the roof sheathing and air-permeable insulation amongst the rafters.

Q. "I are actually using rigid breadboard style expanded polystyrene within the rim joists and imagined the exact same may very well be set underneath the sheathing amongst the rafter bays."

A. I concur. In gentle of the odor situation, I don't Assume that my suggestion to utilize Ice & Water Defend was a great one -- so I withdraw it.

I now understand that stucco can not be applied to a roof, so I will revert towards the a steel roof, but nevertheless want to possess an unvented attic. I have read through by way of "Making a conditioned attic", and am even now unsure as to The easiest way to progress.

In case your weather isn't much too significant It truly is possibly okay to obtain just the R-10 foam around the structural metal, Though you will find some hazard that the steel could sweat in chilly weather conditions. I am assuming You furthermore mght meant to insulate the 2x12 joist bays to get your complete R-benefit to a reasonable amount.

I'd incorporate to Martin's listing of resources for rafter vent channnels, fiberboard sheathing. I take advantage of I joists for vented cathedral ceilings and staple one/2" fiberboard to the bottom of the highest wire with the I joists. It might be ripped with a table observed and installs quickly, fiberboard does have a high perm score and will enable little quantities of moisture to pass through in the vent Place.

Be sure to enter any prior references (earlier shoppers) that you have labored with divided by typing Enter

Thanks, Martin and Stephen. Fortunately we are inside of a condition where we are able to pause and reconsider, as the new felt has become positioned, Nonetheless they haven't started installing shingles but. I'll talk visit their website about the problem with the contractor all over again. I may be able to have him to rethink.

Regardless of whether you decide to make it vented or unvented, get the main points correct — for the reason that every single cathedral ceiling offers opportunities to make huge blunders

It really is definitely not limited to an R eighty Passive Household roof. Choose out the parallel chord trusses and slender it up.

I'm a homeowner in Seattle. Use a recently-framed, vented cathedral ceiling to insulate. Straight bays, 2x12, 24" o/c. The present plan is to work with batts of some form during the bays, choose treatment to air seal the interior surface area, keep away from penetrations, air seal the vent channel as well (bays totally sealed), double prime go to my site The within floor for vapor resistance. I've a few questions about baffling the vent channel: one. Several of the setting up experts I am Performing with really feel the jury is still out on baffles and they are recommending leaving the batts open up for the channel besides near the vents, assuming the 1-2" air channel might be maintained.

Owning spent all my life behind a desk focusing on it is a little bit of a crack. The roof will be carried out in Probably four sections so might consider rigid foam and spray foam to match what will work. Rigid foam is laborous but small sticky residue. Many thanks.

November 18, 2011 Impression one of three A leaky ceiling doomed the roof sheathing. The ceiling of this ten-12 months-old property was cut for an electrical box, as well as the oversized gap was in no way caulked. Moisture-laden air entered the rafter bays via these cracks. Once the humidity encountered cold roof sheathing, it condensed, resulting in humidity accumulation and decay. (The rubberized membrane from the Image was utilized as A short lived patch for your gap within the roof, and didn't lead towards the failure mechanism.) Graphic Credit score: Peter Yost A leaky ceiling doomed the roof sheathing. The ceiling of this 10-12 months-aged dwelling was cut for an electrical box, along why not try these out with the outsized hole was under no circumstances caulked. Moisture-laden air entered the rafter bays as a result of these cracks.

The sides in the roof are lined with asphalt shingled (GAF Slateline to be precise). It appears like I must pull down the fiberglass and have it spray-foamed just before I drywall.